Features

Chamber

Material: titanium + Polysulphone
Shape and dimensions: wedged – base 25 mm x 26.9 mm
Height: 13 mm
Weight: 12 g
Internal volume: 0.82 ml

Septum

Material: silicone
Diameter available for puncture 13 mm
Maximum number of punctures 2000 with 22 GA Huber needle
1000 with 19 GA Huber needle

Max Flow Rate = 5 ml/s with max Pressure 300 PSI,
Max Viscosity 12 cP

POWER PLP

  •  Chamber specifically designed to be used for High- flow Injections of contrast media
  •  Large self-sealing septum facilitates location during skin palpation and reduces risks of puncture concentration
  •  Transparent and radiopaque elastomeric connector allows rapid, safe and reversible connection of the catheter
  •  Low profile plastic chamber, also suitable for patients with
    thick subcutaneous fat layer

POWER PLP

Features

Chamber

Material: titanium + Polysulphone
Shape and dimensions: circular – base diameter 27 mm
Height: 10.6 mm
Weight: 5.9 g
Internal volume: 0.36 ml

Septum

Material: silicone
Diameter available for puncture 13 mm
Maximum number of punctures 2000 with 22 GA Huber needle
1000 with 19 GA Huber needle

Max Flow Rate = 5 ml/s with max Pressure 300 PSI,
Max Viscosity 12 cP

Our Blogs

Polymed Receives ‘India Medical Devices Company of the Year’ Award
The Award, presented by the Government of India, underscores Polymed’s continued leadership position in Medical devices sector Polymed focuses on tapping huge potential in Domestic ...
Read More
Fundamentals, Lets Go Back to Basics
Polymed announces the Academic Initiatives in collaboration with Infusion Nurses Society, India on nursing practices for good nursing care. As the work of nursing becomes ...
Read More
Guarded fistula needle reduces Needle Stick Injuries in Haemodialysis Units
Needle Stick Injuries are injuries caused by accidental penetration of the skin by an injection needle. Globally, NSI’s are the most common source of occupational ...
Read More

Quick Contact

EMAIL

info@polymedicure.com

Call Us

+91 9999 999 999

CAREER

ca@polymedicure.com